2. Groundwater Monitoring Stations Details
This section provides the details for the groundwater monitoring stations
1 Monitoring Station FR00298X0012/F2 - FOR 2
| Unique EU code for the station* |
FR00298X0012/F2 |
| Unique MS code for the station* |
00298X0012/F2 |
| Location (Lon/Lat)* |
3.92425, 50.21244 |
| Name |
FOR 2 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
Yes |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00298X0012/F2/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00298X0012/F2/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| EIONET |
|
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOS
| EU code for programme. |
FRB2SOS |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
2 Monitoring Station FR00384X0029/F1 - FOR 1
| Unique EU code for the station* |
FR00384X0029/F1 |
| Unique MS code for the station* |
00384X0029/F1 |
| Location (Lon/Lat)* |
3.90929, 50.17313 |
| Name |
FOR 1 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
Yes |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00384X0029/F1/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00384X0029/F1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOO
| EU code for programme. |
FRB2SOO |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G016 |
3 Monitoring Station FR00387X0014/P1 - PUITS1
| Unique EU code for the station* |
FR00387X0014/P1 |
| Unique MS code for the station* |
00387X0014/P1 |
| Location (Lon/Lat)* |
3.85356, 50.14229 |
| Name |
PUITS1 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
Yes |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00387X0014/P1/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00387X0014/P1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| EIONET |
|
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOS
| EU code for programme. |
FRB2SOS |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
4 Monitoring Station FR00395X0196/F2 - RASI 2
| Unique EU code for the station* |
FR00395X0196/F2 |
| Unique MS code for the station* |
00395X0196/F2 |
| Location (Lon/Lat)* |
4.01712, 50.04766 |
| Name |
RASI 2 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
Yes |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00395X0196/F2/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00395X0196/F2/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| EIONET |
|
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOS
| EU code for programme. |
FRB2SOS |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
5 Monitoring Station FR00501X0038/HY - SOURCE DU LAVOIR
| Unique EU code for the station* |
FR00501X0038/HY |
| Unique MS code for the station* |
00501X0038/HY |
| Location (Lon/Lat)* |
3.62957, 49.97213 |
| Name |
SOURCE DU LAVOIR |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G017 |
| Type of station.* |
Spring |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
Yes |
| Station is used for chemical operational monitoring.* |
Yes |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00501X0038/HY/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00501X0038/HY/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| EIONET |
|
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOO
| EU code for programme. |
FRB2SOO |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
Programme: FRB2SOS
| EU code for programme. |
FRB2SOS |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
6 Monitoring Station FR00501X0045/S - SOURC1
| Unique EU code for the station* |
FR00501X0045/S |
| Unique MS code for the station* |
00501X0045/S |
| Location (Lon/Lat)* |
3.59411, 49.97050 |
| Name |
SOURC1 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G017 |
| Type of station.* |
Spring |
| Station is used for quantitative monitoring.* |
No |
| Station is used for chemical surveillance monitoring.* |
Yes |
| Station is used for chemical operational monitoring.* |
Yes |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00501X0045/S/ |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/FR00501X0045/S/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| EIONET |
|
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOO
| EU code for programme. |
FRB2SOO |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
No |
Yes |
Not applicable/None |
|
|
|
|
FRB2G017 |
Programme: FRB2SOS
| EU code for programme. |
FRB2SOS |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE2-1 Oxygen content |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-2 pH Value |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-3 Conductivity |
Mesure réalisée de préférence à l'aide de matériel d'analyse de terrain |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-4 Nitrate |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE2-5 Ammonium |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE3 Other pollutants |
Analyse en laboratoire |
No |
Yes |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
7 Monitoring Station FR00383X0229/PZSP6 - Forage des Catiaux (Taisnières en Thiérache) - 59
| Unique EU code for the station* |
FR00383X0229/PZSP6 |
| Unique MS code for the station* |
00383X0229/PZSP6 |
| Location (Lon/Lat)* |
3.82113, 50.14935 |
| Name |
Forage des Catiaux (Taisnières en Thiérache) - 59 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00383X0229/PZSP6 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00383X0229/PZSP6/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
8 Monitoring Station FR00384X0296/PZ4 - Forage de Limont - Fontaine - 59
| Unique EU code for the station* |
FR00384X0296/PZ4 |
| Unique MS code for the station* |
00384X0296/PZ4 |
| Location (Lon/Lat)* |
3.92505, 50.21243 |
| Name |
Forage de Limont - Fontaine - 59 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00384X0296/PZ4 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00384X0296/PZ4/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE1-2 Groundwater yield |
Mesure du débit de la masse d’eau lorsque le site de mesure est une source ou un cours d'eau associé à un aquifère, débit exprimé en m3/s |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
9 Monitoring Station FR00387X0184/PZCC1 - Forage du Campiau (Grand Fayt) - 59
| Unique EU code for the station* |
FR00387X0184/PZCC1 |
| Unique MS code for the station* |
00387X0184/PZCC1 |
| Location (Lon/Lat)* |
3.79404, 50.10950 |
| Name |
Forage du Campiau (Grand Fayt) - 59 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00387X0184/PZCC1 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00387X0184/PZCC1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE1-2 Groundwater yield |
Mesure du débit de la masse d’eau lorsque le site de mesure est une source ou un cours d'eau associé à un aquifère, débit exprimé en m3/s |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
10 Monitoring Station FR00501X0017/S1 - PIEZOMETRE DE VENEROLLES
| Unique EU code for the station* |
FR00501X0017/S1 |
| Unique MS code for the station* |
00501X0017/S1 |
| Location (Lon/Lat)* |
3.63279, 49.98819 |
| Name |
PIEZOMETRE DE VENEROLLES |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G017 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00501X0017/S1 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00501X0017/S1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE1-2 Groundwater yield |
Mesure du débit de la masse d’eau lorsque le site de mesure est une source ou un cours d'eau associé à un aquifère, débit exprimé en m3/s |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
11 Monitoring Station FR00502X0003/S1 - PIEZOMETRE DE ESQUEHERIES - 02
| Unique EU code for the station* |
FR00502X0003/S1 |
| Unique MS code for the station* |
00502X0003/S1 |
| Location (Lon/Lat)* |
3.77414, 49.99508 |
| Name |
PIEZOMETRE DE ESQUEHERIES - 02 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G017 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
No |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00502X0003/S1 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00502X0003/S1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G017 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
| GE1-2 Groundwater yield |
Mesure du débit de la masse d’eau lorsque le site de mesure est une source ou un cours d'eau associé à un aquifère, débit exprimé en m3/s |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G017 |
12 Monitoring Station FR00512X0001/P1 - Puits du service des eaux d'Anord - 59
| Unique EU code for the station* |
FR00512X0001/P1 |
| Unique MS code for the station* |
00512X0001/P1 |
| Location (Lon/Lat)* |
4.12179, 49.99617 |
| Name |
Puits du service des eaux d'Anord - 59 |
| EU code of the groundwater body which the station is physically located on or near. * |
FRB2G016 |
| Type of station.* |
Well |
| Station is used for quantitative monitoring.* |
Yes |
| Station is used for chemical surveillance monitoring.* |
No |
| Station is used for chemical operational monitoring.* |
No |
| Number of subsites normally associated with this station.* |
1 |
| Monitoring depth.* |
Upper |
| Site is used for monitoring of groundwater status |
Yes |
| Site is used for the abstraction of drinking water |
Yes |
| Additional requirements if station is located in a drinking water abstraction site |
Aucune |
| Site is used for industrial supply |
No |
| Site is used for irrigation |
No |
| Site is used for other purposes |
No |
| Brief description of any networks that this station is a part of |
|
| Hyperlink or reference to associated reference statement or file |
http://www.ades.eaufrance.fr/FichePtEau.aspx?code=00512X0001/P1 |
| URL to further information: |
http://www.surveillance.eaufrance.fr/eaux-souterraines/site/00512X0001/P1/ |
International Networks
International networks that this station is part of, if any
| Name of the network |
Unique code for the station in this network |
| International Commission for the Meuse |
|
Programmes
This section describes the Article 8 programmes that the station is part of. The stations are linked to the programme using the code of the programme. A station may be part of more than one programme
Programme: FRB2SOP
| EU code for programme. |
FRB2SOP |
| Waterbodies monitored by this station |
FRB2G016 |
Parameters measured at the station for this programme
If this section is empty, then it is assumed that all parameters defined in the programme are monitored for each associated waterbody.
| Parameter Code* |
How measured |
Quantitative |
Chemical Surveillence |
Chemical Operational |
Subsites |
Frequency |
Cycle |
Cycle description |
Reason for deviation |
Waterbodies |
| GE1-1 Groundwater level |
Mesure du niveau piézométrique de la masse d'eau lorsque le site de mesure est un piézomètre ou un forage, niveau exprimé en mètres (m) |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |
| GE1-2 Groundwater yield |
Mesure du débit de la masse d’eau lorsque le site de mesure est une source ou un cours d'eau associé à un aquifère, débit exprimé en m3/s |
Yes |
No |
No |
Not applicable/None |
|
|
|
|
FRB2G016 |